ENGLISH 9
Typeofgasused Typeof
burner
Injector
marking
Nominal
heating
capacity
kW
Nominal
consum-
ption
Reduced
heat
capacity
kW
Gaspressure
(mbar)
min. nom. max.
NATURALGAS
(Methane)
G20
rapid
semi-rapid
auxiliary
129B
104B
74B
3,00
1,90
1,00
286l/h
181l/h
95l/h
0,60
0,35
0,30
17 20 25
LIQUEFIED
PETROLEUMGAS
(Butane)G30
rapid
semi-rapid
auxiliary
86
70
50
3,00
1,90
1,00
218g/h
138g/h
73g/h
0,60
0,35
0,30
20
28
30
35
LIQUEFIED
PETROLEUMGAS
(Propane)G31
rapid
semi-rapid
auxiliary
86
70
50
3,00
1,90
1,00
214g/h
136g/h
71g/h
0,60
0,35
0,30
25 37 45
Injectortable
CategoryII2H3+
Typeofgas
used
Model
conguration
Nominalheating
capacitykW
Totalnominal
consumption
Airnecessary
(m
3
)for
combustion
1m
3
ofgas
G2020mbar 4gas 7,80 743l/h 9,52
G3028-30mbar 4gas 7,80 567g/h 30,94
G3137mbar 4gas 7,80 557g/h 23,80
ElectricPower:230V~50Hz