ENGLISH 8
Extraction speed (power) selection is cyclic
according to the speed sequence
therefore every time the “extraction power
selection” button is pressed, the extraction
speed (power) increases by one level
and switches off (Stand-by) if the button
is touched again when the hood is on
extraction speed (power) 4.
Note: Extraction speed (power) 4 remains
on for 5 minutes, after which the extraction
motor switches to speed 2.
By pressing it again the extraction motor
switches off (Stand-by).
The hood can also be switched off (Stand-
by) when it is on any speed, by prolonged
pressing (more than 3 seconds) of the
button.
The control panel has a led that changes
colour according to the extraction speed
(power), therefore hood extraction speed
(power) can be determined as follows:
Hood on stand-by: LED OFF
extraction speed
(power) 1: Led GREEN
extraction speed
(power) 2: Led ORANGE (amber)
extraction speed
(power) 3: Led RED
extraction speed
(power) 4: Led RED FLASHING
Controlofbottomlamps
The bottom light can be switched on or off
by pressing the “light button”.
Controlofinsidelamps
The inside lights can be switched on or
off by PROLONGED pressing of the “light
button”.
As well as as switching on and off,
PROLONGED PRESSING also allows the
brightness of the lamps to be adjusted.
Note: the switching on and off (and
adjustment) functions alternate.
Reset and conguration of lter saturation
signalling
Switch the hood on at any speed (see
section above “Extraction speed (power)
control”)
Resetgreaseltersaturationsignalling
(GREENLEDFLASHINGoncontrolpanel)
Firstly carry out lter maintenance as
described in the relevant section.
Press (prolonged for more than 3 seconds)
the “extraction power selection” button; the
LED stops ashing to indicate that
signalling has been reset, and the hood
switches off.
Resetcarbonltersaturationsignalling
(ORANGE(amber)LEDFLASHING)
Firstly carry out lter maintenance as
described in the relevant section.
Press (prolonged for more than 3 seconds)
the “extraction power selection” button; the
LED stops ashing to indicate that
signalling has been reset, and the hood
switches off.
Deactivationofcharcoalltersaturation
signalling(forparticularapplications)
Switch off the hood (see section above
“Extraction speed (power) control”)
Press (prolonged for more than 5 seconds)
the “extraction power selection” button; the
LED ashes GREEN (amber) to
indicate that carbon lter saturation
signalling has been deactivated.
To reactivate charcoal lter saturation
signalling, repeat the operation, and the
LED will ash ORANGE.