IKEA HBT E70 S Instrucciones de uso Pagina 11

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 88
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 10
ENGLISH 11
Type of gas used Type of
burner
Injector
marking
Rated
thermal
ow rate
kW
Rated
consumption
Reduced
heat
capacity
kW
Gas pressure
(mbar)
min. rat. max.
NATURAL GAS
(Methane)
G20
power burner
rapid
semi-rapid
auxiliary
145
118 F2
101 Z
72 X
4,00
3,00
2,00
1,00
381 l/h
286 l/h
190 l/h
95 l/h
2,20
0,60
0,35
0,30
17 20 25
LIQUEFIED
PETROLEUM GAS
(Butane) G30
(Propane) G31
power burner
rapid
semi-rapid
auxiliary
96
85
69
50
3,80
3,00
2,00
1,00
276 g/h
218 g/h
145 g/h
73 g/h
1,90
0,60
0,35
0,30
25 30 35
Injector table
Category II2H3B/P
Type of gas
used
Model
conguration
5 BURNERS
Rated thermal
owrate (kW)
Total rated
consumption
Air required (m
3
)
for burning1m
3
of
gas
G20 20 mbar
1 PB - 1 R
2 SR - 1 AUX
12,00 1142 l/h 9,52
G30/31
30 mbar
1 PB - 1 R
2 SR - 1 AUX
11,80 857 g/h 30,94
Electric Power: 220 - 240 V ~ 50/60 Hz
SV
G110/G120-8 mbar gas set nozzle
are available through after-sales service
only.
DK
G110-8 mbar gas set nozzle are
available through after-sales service only.