The replacement of the electrical
cable must be done by a
qualified electrician or
competent person, according to
the current regulations.
Replacement of the connection cable
Warning! The replacement of
electric cable must be carried out
exclusively by the After Sales
Service or by personnel with
similar competencies, in
accordance with the current
regulations.
If the connection cable must be replaced,
only a type H05V2V2-F T90 cable must be
used. The cable section must be suitable to
the voltage and the working temperature.
The yellow/green earth wire must be
approximately 2 cm longer than the brown
(or black) phase wire.
Gas setting conversion
This model is designed for use
with natural gas but can be
converted for use with butane or
propane gas providing the
correct injectors. The injectors not
supplied with the appliance have
to be ordered from After Sales
Service (refer to the Service
chapter).
For data concerning injector replacement,
refer to the chapter Technical data.
Warning! Conversion or
replacement can only be
performed by a registered
installer.
To replace injectors:
1. Remove pan support.
2. Remove burner cap and crown.
3. With a socket spanner 7 unscrew and
remove the injectors, replace them with
the ones required for the type of gas in
use.
4. Reassemble the parts, following the
same procedure backwards.
Place the label with relevant
information for new type of gas
close to the supply pipe before
sealing the appliance. If the
appliance is already sealed
please stick it directly on the user
manual booklet after Technical
data chapter close to the rating
plate drawing.
You can find this label in
package supplied with
appliance.
If the feeding gas pressure will
be different or variable,
comparing with the required, you
must install an appropriate
pressure adjuster, which is not
supplied with the product and if
needed must be ordered
separately from the local After
Sales Service (refer to the Service
chapter). The pressure adjuster
must be fitted on gas supply
pipe, in compliance with the rules
of the force.
The rating plate is located on the lower
casing of the hob.
Adjusting flame level
When hob has been fully installed, it is
necessary to check the minimum flame
setting:
1. Turn the gas tap to the maximum
position and ignite.