The minimum distance to be maintained
from cut out edge to lateral wall must be
100 mm.
If there is no oven beneath the hob insert a
dividing panel at a minimum distance of 5
mm from the bottom of the hob.
Protect the cut surfaces of the worktop
against moisture using a suitable sealant
included in the product in additional bag.
Seal the appliance to the worktop with no
gap. Do not use silicon sealant between the
appliance and the worktop. Do not install
the appliance next to the doors and under
windows. Otherwise, the hot cookware may
fall off the pan supports.
Electrical connection
Warning! Refer to Safety
chapters.
Connection cable
Caution! Information for
authorised installer only.
Warning!
The appliance must be earthed.
Warning!
Risk of injury from electrical
current.
• The electrical mains terminal is under
voltage.
• Make sure that the electrical mains
terminal is free of voltage.
• Loose and inappropriate plug and
socket connections. May overheat the
terminal.
• Make sure that the clamping connections
are installed correctly.
• Secure the cable with the strain relief
clamp.
Before connecting, check that the nominal
voltage of the appliance stated on the
rating plate, corresponds to the available
supply voltage. Also, check the power
rating of the appliance and make sure that
the wire is suitably sized to suit the
appliance power rating. Refer to the
Technical data chapter.
The rating plate is located below the
surface of the casing.
The appliance is supplied with a connection
cable. The cable must be provided with a
proper plug, which supports the load
marked on the identification plate. Refer to
the Technical data chapter.
The plug has to be fitted in a proper socket.
If connecting the appliance directly to the
electric system, it is necessary that you
install a double pole switch between the
appliance and the electricity supply, with a
minimum gap of 3 mm between the switch
contacts. The double pole has to be of a
type suitable for the required load in
compliance with the current rules.
The connection cable has to be placed in
order that, in each part, it cannot reach a
90 °C temperature. The blue neutral cable
must be connected to the terminal block
marked with "N". The brown or black phase
cable, fitted in the terminal block contact
marked with "L", must always be connected